Tên sản phẩm: Gas detector
Mã sản phẩm : MD-2000R
Xuất xứ : VIETSENS - FOCUS
Bảo hành: 12 tháng (chi tiết)
|
|
 |
-
Using the advance low current gas sensitive component, it can detector the release of gas in time.
-
Using advance wireless signal, wired and wireless alarm output compatible.
-
Can be adjusted according to the practical environment, reduce the false alarm rate.
-
Good design, easy for installation. |
 |
| THÔNG SỐ KỸ THUẬT |
 |
-
Using the advance low current gas sensitive component, it can detector the release of gas in time.
-
Using advance wireless signal, wired and wireless alarm output compatible.
-
Can be adjusted according to the practical environment, reduce the false alarm rate.
-
Good design, easy for installation.
【 Parameter 】
|
Sensitive gas |
coal gas, natural gas, liquefied petroleum gas |
|
Power input |
AC220V/50Hz |
|
Buzzer |
≥70db/m |
|
Alarm thickness |
15%LEL |
|
Renew thickness |
8%LEL |
|
Environment |
-10℃-+40℃ |
|
Humidity |
<90%RH |
|
stability |
For long time work, the thickness not above ±5%LEL |
|
Renew |
Renew test alarm not above ±5%LEL |
|
Alarm thickness error |
Not above ±5%LEL |
|
Alarm model |
Sound and lighting alarm, network signal output |
|
Power consumption |
Not above 5 W | |
|
|
SẢN PHẨM CÙNG LOẠI |
| + MD-2008 |  |
-
Using self design patent technology, has reliable function for anti false alarm, and miss alarm.
-
The networking signal including NO, NC, and battery out put modes,it can use the network signal start up the fans.
-
Fit for using together with many low voltage electronics, such as alarm detectors.
-
High stability, long life, wall mounting installation, low consumption.
-
After Alarm situation eliminate, renew automatically. | | + LH-86 |  |
-
Đầu báo dò khí ga, MCU processing, Ceiling Mounted
-
Detecting Gas:Town Gas.CO, Auto Reset After Alarm
-
Xuất xứ: Longhorn - Taiwan
-
BH 1 năm | | + MD-2018 |  |
-
Standard caliber: G1/2 (DN15) G4 (DN100)
-
Working temperature: -10℃-+60℃
-
Max working pressure: 0.5db, 1db
-
Using gas type: Natural gas, coal gas, liquefied petroleum gas
-
Valve open mode: manual for replacement
-
Valve close mode: low voltage impulse drive / manual
-
Drive voltage: DC6v, 9v, 12v, 24v (impulse)
-
Time for close valve: 1 second
-
Continuous recharge time: 30s
-
Keeping mode: keep valve on/ off state
-
IP grade: IP54 | | + MD-2206 |  |
-
Using self design patent technology, has reliable function for anti false alarm, and miss alarm.
-
The networking signal including NO, NC, and battery out put modes,it can use the network signal start up the fans.
-
Fit for using together with many low voltage electronics, such as alarm detectors.
-
High stability, long life, wall mounting installation, low consumption. | | + MD-2000R |  |
-
Using the advance low current gas sensitive component, it can detector the release of gas in time.
-
Using advance wireless signal, wired and wireless alarm output compatible.
-
Can be adjusted according to the practical environment, reduce the false alarm rate.
-
Good design, easy for installation. | |
|
|
|
|
|